Technical data · 16 mm dry system

Everything technically important. In one place.

From the system panel and pipework to hydraulics and controls — a clear overview of the elements behind a safe, precise and efficient installation.

System cross-section

Minimal build-up. Serious engineering detail.

A low-profile system requires the board, pipe, aluminium layer, substrate and floor finish to be designed as one assembly.
16 mmEN 312 · P201
12 × 1.5 mmPE-RT · EVOH02
8–12.5 cmpipe spacing03
5–15 m/m²depending on layout04
Layers of a dry underfloor heating system16mm

01 · System panel

A precisely routed system base.

The 16 mm P2 panel has factory-routed channels into which the pipe is pressed. Full-surface aluminium lamination supports rapid and even heat transfer towards the floor finish.

Material
P2 panel to EN 312
Use
Dry interior conditions
Channels
For 12 × 1.5 mm pipe
Layout
Project-specific
Lamination
Full-surface aluminium layer
Production
Made in Germany

02 · Heat output

A number without context is not a calculation.

Output depends on water temperatures, floor-covering resistance, pipe spacing, downward insulation and permitted floor-surface temperature.
0150–70 W/m²

efficient working range

Indicative range from the supplied information for a well-coordinated floor assembly.

0280–100 W/m²

higher room demand

Possible in selected assemblies after checking the floor finish and surface temperature.

03up to 110 W/m²

specific conditions

For example bathrooms; always subject to project calculation.

01floor finish and adhesive02flow and return temperature03downward insulation04circuit length and flow05permitted surface temperature

Values are indicative and based on the supplied technical content. Final output and flow temperature require a project-specific calculation.

03 · System components

Pipe and adhesive do invisible work.

The specification of every supplied component is confirmed by the manufacturer’s current technical data sheet.
01

PE-RT heating pipe

Five-layer pipe with an EVOH oxygen-diffusion barrier, intended for surface heating and compact circuits.

Size
12 × 1.5 mm
Construction
5-layer PE-RT + EVOH
Coils
100 m / 300 m
Bend radius
≈ 5 × outside diameter
Temperature range*
5–80 °C
Short-term load*
up to 95 °C
02

System composite adhesive

Solid-elastic, single-component adhesive for full-surface indoor bonding, free of water and solvents.

Base
silane-modified polymer
Emission class*
EMICODE EC1 PLUS
Open time*
≈ 40 min
Further work*
≈ 12–24 h
Reference consumption*
≈ 1,000 g/m²

* Applies only to the selected product stated in the quotation and its current technical data sheet.

04 · Building physics

The system is part of the floor — not a substitute for it.

01

Moisture

P2 panels are intended for dry interiors. Bathrooms and wet zones require a professionally executed complete waterproofing assembly.

02

Fire

Reaction to fire depends on the selected panel and full assembly. Buildings with specific requirements need a certified solution defined by the fire-safety design.

03

Insulation

The system panel is not thermal insulation. U-value and downward heat flow depend on the substrate and insulation type and thickness.

04

Loads

Permitted loading is checked for the complete layered floor and its actual use — without universal promises in tonnes per square metre.

05 · Hydraulics and controls

Every room receives exactly what it needs.

Manifold, circuits, flow rates, actuators and room controls are coordinated in the design so the system performs predictably after commissioning.
230 V · 6–10 zonesNC / NO thermal actuatorsoptional pump logicoptional Wi-Fi controlhydraulic balancing
01

Circuit design

Layout, lengths and zones tailored to each room.

02

Manifold

Flow balancing and clear service access.

03

Room control

Wired, wireless or smart options to suit the project.

04

Commissioning

Pressure, flow and function checks for every zone.

Technical support

Send the floor plan. We’ll return with a concrete system.

Receive a board and circuit layout, component specification and a sound basis for installation — tailored to the actual building.This overview is informative. The project, quotation and current component data sheets supplied for the specific system are authoritative.